Avantis 75

High Performance windows

Avantis 75 is a thermally broken three-chamber window and door system, which sets the highest standards of thermal insulation and stability. Avantis 75 is the ideal solution when very high performance and quality are major requirements.

Avantis 75 description

  • Avantis 75 profiles have 3 chambers, coupled with 40 mm tubular shaped, glass fibre reinforced polyamide strips, which drastically reduce thermal conduction. The result is that Avantis 75 achieves a very high thermal performance level and improved total insulation, leading to lower total energy consumption, a positive benefit to the environment.
  • The system is available in 4 modular thermal values, to meet closer the requirements of the construction.
  • The system accommodates glazing up to 60,5 mm for frame and 70 mm for vent, the infill thickness can start from 4 mm.
  • Inward opening vents have a coextrusion central gasket for enhanced thermal and acoustic performance.
  • All standard shade and ventilation systems can easily be integrated in Avantis 75.

Thermicity

Avantis 75 Basic

  • Uf = 1,99 W/m2K - 2,53 W/m2K

Avantis 75 I

  •  Uf = 1,82 w/m2K - 2,31 W/m2K
  • Improved thermal glazing gaskets
  • Improved thermal central gasket

Avantis 75 SI

  • Uf = 1,03 w/m2K - 2,03 W/m2K
  • Improved thermal glazing gaskets & central gasket
  • PE inserts in frame and vent profile

Avantis 75 SHI

  • Uf = 0,92 w/m2K - 1,95 W/m2K
  • Improved thermal glazing gaskets & central gasket
  • PE inserts in frame and vent profile
  • PE insert thermal improved glazing unit

Avantis 75 Designs

  • Avantis 75 is compatible within its profile and hardware range, as well as other Sapa Building System products such as our curtain wall and conservatory systems.
  • Available designs: Classic, Softline, Rustic and Hidden Vent.
  • Hidden drainage to avoid the requirement for cover caps.
  • Doors of existing Excellence 75 SI are fully compatible.
  • A comprehensive range of supplementary finishing profiles allows the fenestration to be integrated perfectly into the building.
  • Vent, frame and transom profiles are available in a range of dimensions to meet the needs of stability and design requirements.
  • A wide choice of hinges, handles and hardware finalise your specific needs.
  • Designer glazing beads add extra finish.

Characteristics

Dimensions
Mininum sightline fixed frame 50 mm
Minimum sightline window with inward opening vent 89 mm
Minimum sightline window with outward opening vent 99 mm
Minimum sightline transom 72 mm
Profile depth frame / building depth 75 mm
Profile depth vent 85 mm
Maximum window (width x height) 1600 x 2400 mm
 
Glazing
Rebate height 22 mm
Infill thickness fixed frame 4 - 60 mm
Infill thickness vent frame 10 - 70 mm
Glazing method dry glazed with EPDM gaskets or silicon

Performances

Thermal insulation

Basic: Uf = 1,99 - 2,53 W/m2K

Thermal insulation

Results of the calculation of the thermal transmittance of frame profiles and of the linear thermal transmittance of their junction with glazing or opaque panels

Norm

EN ISO 10077-2

Thermal insulation

Insulated: Uf = 1,82 - 2,31 W/m2K

Thermal insulation

Results of the calculation of the thermal transmittance of frame profiles and of the linear thermal transmittance of their junction with glazing or opaque panels

Norm

EN ISO 10077-2

Thermal insulation

Super Insulated: Uf = 1,03 - 2,03 W/m2K

Thermal insulation

Results of the calculation of the thermal transmittance of frame profiles and of the linear thermal transmittance of their junction with glazing or opaque panels

Norm

EN ISO 10077-2

Thermal insulation

Super High Insulated: Uf = 0,92 - 1,95 W/m2K

Thermal insulation

Results of the calculation of the thermal transmittance of frame profiles and of the linear thermal transmittance of their junction with glazing or opaque panels

Norm

EN ISO 10077-2

Air Tightness

4 - 600 Pa

Air Tightness

Air tightness refers to the amount of air that will travel through a window or door system in its closed position, both under positive and negative pressure.

Norm

EN 12207

Water Tightness

E1200 - 1200 Pa

Water Tightness

The test applies specified amounts of water spray to the outside face of the window (combination) while incrementally increasing the air pressure. The result defines the test pressure, time and position of any water infiltration.

Norm

EN 12208

Wind Resistance

C5 - 2000 Pa (security 3000 Pa)

Wind Resistance

The test applies a series of positive and negative test air pressures. Measurements and inspections are made to asses relative frontal deflection and resistance to damage from wind loads.

Norm

EN 12210

Acoustic Insulation

Rw (C;Ctr) = 50 (-2;-4) dB (88.2/15/66.2)

Acoustic Insulation

defines single-number quantities for airborne sound insulation in buildings and of window (combinations)

Norm

EN ISO 717/1

Forced Entry Resistance

class 2

Forced Entry Resistance

Description for Forced Entry Resistance

Norm

EN 1627 - 1630

Applications

fixed window

turning window inwards opening

tilt-turn window inwards opening

Double inwards turning window

double inwards opening window; one turning vent, one tilt-turn vent

horizontally pivoting window

turning window outwards opening

Double outwards opening window

Tilt-slide door

Technical sections

Building Information Models

Sapa BIMselector

Building Information Modeling (BIM) is a digital representation of physical and functional characteristics of our aluminium window and door systems. We have created many different applications of our systems and offer them - free of charge - for download on the Sapa BIMselector.

Go to Sapa BIMselector

Documentation

PB_Avantis75_BRen_092015.pdf PB_Avantis75_BRen_092015.pdf
PB_Avantis75_BRen_092015.pdf
Download 900 KB

Product overview

Avantis 75 is a thermally broken three-chamber window and door system, which sets the highest standards of thermal insulation and stability. Avantis 75 is the ideal solution when very high performance and quality are major requirements.

SAPA BUILDING SYSTEMS -
Please choose your language